Low Voltage Circuit Breakers (LV CBs)
Low Voltage Circuit Breakers (LV
CBs) are electrical devices used to
protect electrical circuits from damage due to overloads, short circuits, and
other electrical faults. These circuit breakers operate at low voltages
(typically up to 1,000 V AC or 1,500 V DC) and are commonly used in residential,
commercial, and industrial electrical installations.
Key Features of Low Voltage Circuit Breakers:
- Protection Functionality:
- Overload Protection:
Protects circuits from prolonged overloads that could cause overheating
and damage.
- Short-Circuit Protection: Prevents severe damage caused by a short circuit by
disconnecting the circuit instantly.
- Earth Fault Protection: Some LV CBs provide earth fault or ground fault
protection to detect leakage currents.
- Selective Tripping:
In more advanced LV CBs, multiple breakers can be coordinated to allow
only the breaker nearest to the fault to trip, preserving the rest of the
system.
- Types of Low Voltage Circuit Breakers: LV CBs come in different types, each designed to suit
specific applications and provide various levels of protection. The main
types include:
- Molded Case Circuit Breakers (MCCBs):
- MCCBs are used for protecting both residential and
industrial systems with current ratings from 15 A to 1,250 A.
- They offer both thermal and magnetic protection and
can be used in various applications, from motor circuits to power
distribution.
- MCCBs can be adjustable in terms of the
overload protection setting, providing flexibility for different
applications.
- Miniature Circuit Breakers (MCBs):
- MCBs are designed for protecting circuits in
residential, commercial, and light industrial applications.
- They are typically rated for current up to 100 A and
are used to protect individual circuits (e.g., lighting or power
circuits).
- MCBs offer thermal-magnetic protection
(thermal for overload, magnetic for short circuits).
- MCBs are usually available in different tripping
curves (types B, C, and D) to suit different load characteristics:
- Type B:
Trips between 3-5 times the rated current (typically used for lighting
and resistive loads).
- Type C:
Trips between 5-10 times the rated current (used for inductive loads
like motors).
- Type D:
Trips between 10-20 times the rated current (used for high inrush
current loads such as transformers).
- Residual Current Circuit Breakers (RCCBs):
- RCCBs are designed to protect against electric shocks
and earth faults by detecting leakage currents between the live
conductors and earth.
- RCCBs do not provide overcurrent protection but are
typically used in combination with MCBs for complete protection.
- Combination Breakers (RCBOs):
- RCBOs combine the functionalities of both an MCB and
an RCCB, offering overload, short-circuit, and earth
leakage protection in a single unit.
- These are commonly used in applications where both
overcurrent and leakage protection are required in one device.
- Air Circuit Breakers (ACBs):
- ACBs are designed for higher current applications
(typically above 100 A).
- They are used in high-power distribution systems
and are often used in industrial environments.
- ACBs offer both thermal and magnetic protection
and may also include adjustable settings for overload and
short-circuit protection.
Key Characteristics of Low Voltage Circuit Breakers:
- Rated Current (I_n):
- The rated current is the maximum continuous current
that the circuit breaker can safely carry without tripping. For example,
an MCB may have a rated current of 10 A, 16 A, 20 A, etc.
- Breaking Capacity (I_c):
- The breaking capacity (also called fault current
rating) is the maximum short-circuit current the circuit breaker can
safely interrupt without causing damage to itself or the circuit. The
higher the breaking capacity, the more fault current the circuit breaker
can handle.
- Common ratings are 6 kA, 10 kA, 15 kA, 25 kA, etc.
- Tripping Characteristics:
- Thermal Tripping:
Activated by an overload condition where current exceeds the rated value
over a period of time.
- Magnetic Tripping:
Activated by a sudden surge of current caused by short circuits.
- Selective Tripping:
Ensures that only the breaker closest to the fault trips, leaving the
rest of the system unaffected.
- Voltage Rating:
- The voltage rating indicates the maximum voltage at which
the circuit breaker can operate safely. Most LV CBs are rated for
230V/400V AC, which is standard in most residential and industrial
systems.
- Tripping Curves (for MCBs):
- These curves represent the time vs. current
characteristic for how fast the breaker will trip in response to an
overload. Each curve (B, C, D) defines the multiple of the rated current
at which the breaker will trip and the duration of that trip.
- Type B:
Commonly used for general-purpose loads with moderate inrush currents
(e.g., lighting).
- Type C:
Commonly used for inductive loads like motors.
- Type D:
Used for loads with high inrush currents (e.g., transformers, large
motors).
- Standards and Compliance:
- Low Voltage Circuit Breakers are designed and tested
according to international standards like:
- IEC 60947-2:
For low voltage circuit breakers.
- UL 489:
For circuit breakers for overcurrent protection.
- ANSI/IEEE C37:
For industrial circuit breakers in the U.S.
Applications
of Low Voltage Circuit Breakers:
- Residential Wiring:
- MCBs are used to protect individual circuits for
lighting, power outlets, and appliances.
- RCCBs or RCBOs are also used to protect against
electric shocks due to earth faults.
- Commercial Buildings:
- MCBs are used to protect lighting and power circuits.
- MCCBs can be used to protect higher current circuits,
such as air conditioning systems or large electrical panels.
- RCCBs are installed to protect personnel from
electrical shock hazards.
- Industrial Applications:
- MCCBs are used for motor protection, power
distribution, and other heavy-duty circuits.
- ACBs are used in high-power systems for their ability
to handle large fault currents.
- Soft starter and VFD motor circuits often use specific
MCBs or MCCBs.
- Motor Control:
- For motor protection, a combination of MCCBs, MCBs,
and overload relays is commonly used to protect motors from
overloads, short circuits, and phase failure.
Example of Sizing a Low Voltage Circuit Breaker for a Motor:
Let’s say we need to protect a 5
HP motor operating on a 400V 3-phase system.
- Calculate the Full-Load Current (FLC):
- For a 5 HP motor, the FLC is typically around 9.5 A
(based on the motor's power rating and efficiency).
- Select the Circuit Breaker Type:
- Based on the motor type and starting conditions (DOL,
star-delta, etc.), select an MCB or MCCB that can handle
the starting current and any possible overloads.
- Overload Setting:
For motor protection, the overload relay or breaker should be set at 115-125%
of the motor FLC, which in this case would be around 11 A to 12 A.
- Breaking Capacity:
- Choose a breaker with an appropriate breaking capacity
based on the expected fault currents. For most standard installations, 10
kA or 15 kA breaking capacity is sufficient.
Conclusion:
Low Voltage Circuit Breakers are
essential for ensuring the safety and reliability of electrical installations
by protecting circuits from overloads, short circuits, and fault currents.
Selecting the appropriate type of breaker, properly sizing it based on load
characteristics, and ensuring compliance with industry standards is critical
for the effective operation of electrical systems. Whether you are using MCBs
for residential circuits or MCCBs and ACBs for industrial systems, each breaker
type offers specific protection and is suited to different applications.